Slab soffit strengthening bonds carbon fibre laminate strips under an existing slab with structural epoxy to add bending capacity — for new loads, a change of use or reinforcement lost to corrosion. The engineer designs the layout; we repair and prepare the substrate, install to the manufacturer's method and record every hold point.

Carbon fibre laminate strips being bonded to a concrete slab soffit in a Sydney car park

When a slab needs more capacity

Laminate strips usually get called up under a slab for one of a few reasons: a change of use that needs more live-load capacity, heavier plant or vehicles on a car park or roof, design or construction shortfalls found in an investigation, or reinforcement lost to concrete cancer past what patching restores.

How we do it

  1. Start from the engineer's design — strip layout, layers and anchorage come off the drawings. If cracks need injecting first or the design isn't final, we flag it before we price.
  2. Repair and prepare — defective concrete is repaired back to sound material, then the soffit is ground or blasted to the profile the system requires.
  3. Bond — factory-cured laminate strips bonded with structural epoxy to the manufacturer's method.
  4. Test and record — pull-off tests where specified, batch records and installation ITPs packaged for the engineer's hold point.

Questions builders ask

How long before the slab can take load?

The install is usually quick; cure sets the pace. Epoxy cure depends on temperature and the system, so the loading date comes from the manufacturer's data and the engineer — we set it out in the price so it's in your program.

Can you work over an occupied floor?

Yes. Grinding is the noisy, dusty part and goes to the hours your site allows, with extraction running. Bonding is quiet with no hot works.

Does it need fire protection?

Sometimes. Where the slab needs a fire rating, the engineer or fire engineer specifies a protective board or coating over the fibre — plan it into the program early.

Related work

Part of carbon fibre strengthening. See also strengthening around openings and penetrations, beam and shear strengthening, column and pier wrapping, pull-off testing. Spalled or corroded concrete is repaired first under concrete cancer repair.

Send us the engineer's strengthening design or photos — we respond within the hour.

Aussie Concrete Repair
Aussie Concrete Repair
Concrete repair crews for builders · Sydney-wide
ACRA member · NSW Licence 360636C · 0410 515 509
Get a quote →or quotes@aussieconcreterepair.com.au
Same scope on your project?

Send us the spec. We'll price it.

Send the engineer's spec, drawings or site photos — whatever you've got. We read it and call you back within the hour. No call centre, no obligation.

✓1-hour callback, quotes within 7 days.
✓You deal with the crew that does the work.
✓Itemised price, built to the engineer's spec.
★ACRA member · NSW Licence 360636C
Get a quote
Tell us about the project. We call back within the hour.
Max file size 10MB.
Uploading...
fileuploaded.jpg
Upload failed. Max size for files is 10 MB.
We call back within the hour. No spam, ever.
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
📞Get a quote →